검색
검색 팝업 닫기

Advanced search

Article

Split Viewer

Korean J Thorac Cardiovasc Surg 1992; 25(3): 307-314

Published online March 5, 1992

Copyright © Journal of Chest Surgery.

Internal Mammary Artery Grafting Without Intraluminal Dilatation - Measurement of Internal Mammary Artery Flow and Clinical Results -

최종범,윤재도,박양규,박옥규

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

The internal mammary artery has been advocated for use in bypass grafting owing to its superior long-term patency when compared to saphenous vein grafts. Concern exists that the flow through internal mammary artery may be inadequate during periods of peak myocardial demand when the internal mammary artery graft was used for proximal left anterior descending artery stenosis. This flow adequacy was investigated in 13 consecutive patients with a mean proximal left anterior descending artery stenosis of 84.2% who were selected for coronary bypass using internal mammary artery. We checked flow and diameter of left internal mammary artery without intraluminal dilatation just before anastomosis to left anterior descending artery during cardiopulmonary bypass. Clinical results were evaluated postoperatively with clinical symptoms, echocardiographies, stress tests, and coronary angiographies. The mean internal mammary artery flow measured just before anastomosis was 38ml/ min[range of 20 to 80ml /min] and its mean internal diameter 1.4mm. Maximal workload was improved from preoperative value of 6.3±2.5METS to postoperative value of 9.1±1.4 METS in 9 patients who Paired-test can be used. Cardiac symptoms recurred in two patients after bypass surgery, but they were not related to left internal mammary artery grafts. All patients were discharged in postoperatively 9.3 days[range of 7 to 20 days] after operation without mortality. Thus, on the basis of these findings, the internal mammary artery is a reasonable graft that we can routinely use for proximal left descending artery stenosis if internal diameter of the internal mammary artery is more than 1.0mm and its flow is more than 20ml /min at mean arterial pressure of 50 to 60mmHg during cardiopulmonary bypass.

Article

Korean J Thorac Cardiovasc Surg 1992; 25(3): 307-314

Published online March 5, 1992

Copyright © Journal of Chest Surgery.

Internal Mammary Artery Grafting Without Intraluminal Dilatation - Measurement of Internal Mammary Artery Flow and Clinical Results -

최종범,윤재도,박양규,박옥규

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

The internal mammary artery has been advocated for use in bypass grafting owing to its superior long-term patency when compared to saphenous vein grafts. Concern exists that the flow through internal mammary artery may be inadequate during periods of peak myocardial demand when the internal mammary artery graft was used for proximal left anterior descending artery stenosis. This flow adequacy was investigated in 13 consecutive patients with a mean proximal left anterior descending artery stenosis of 84.2% who were selected for coronary bypass using internal mammary artery. We checked flow and diameter of left internal mammary artery without intraluminal dilatation just before anastomosis to left anterior descending artery during cardiopulmonary bypass. Clinical results were evaluated postoperatively with clinical symptoms, echocardiographies, stress tests, and coronary angiographies. The mean internal mammary artery flow measured just before anastomosis was 38ml/ min[range of 20 to 80ml /min] and its mean internal diameter 1.4mm. Maximal workload was improved from preoperative value of 6.3±2.5METS to postoperative value of 9.1±1.4 METS in 9 patients who Paired-test can be used. Cardiac symptoms recurred in two patients after bypass surgery, but they were not related to left internal mammary artery grafts. All patients were discharged in postoperatively 9.3 days[range of 7 to 20 days] after operation without mortality. Thus, on the basis of these findings, the internal mammary artery is a reasonable graft that we can routinely use for proximal left descending artery stenosis if internal diameter of the internal mammary artery is more than 1.0mm and its flow is more than 20ml /min at mean arterial pressure of 50 to 60mmHg during cardiopulmonary bypass.

There is no Figure.

There is no Table.

There is no Reference.

Stats or Metrics

Share this article on :

  • line