Korean J Thorac Cardiovasc Surg 2016; 49(3): 145-150

Published online June 5, 2016 https://doi.org/10.5090/kjtcs.2016.49.3.145

Copyright © Journal of Chest Surgery.

The Effect of Pulsatile Versus Nonpulsatile Blood Flow on Viscoelasticity and Red Blood Cell Aggregation in Extracorporeal Circulation

Chi Bum Ahn1, Yang Jun Kang2, Myoung Gon Kim2, Sung Yang2, Choon Hak Lim3, Ho Sung Son4, Ji Sung Kim5, So Young Lee5, Kuk Hui Son5, and Kyung Sun4

1Department of Molecular Medicine, Gachon University Graduate School of Medicine, 2Department of Mechatronics, Gwangju Institute of Science and Technology, 3Department of Anesthesiology and Pain Medicine, Korea University Medical Center, 4Department of Thoracic and Cardiovascular Surgery, Korea University Medical Center, 5Department of Thoracic and Cardiovascular Surgery, Gachon University Gil Medical Center, Gachon University College of Medicine

Correspondence to:Corresponding author: Kuk Hui Son, Department of Thoracic and Cardiovascular Surgery, Gachon University Gil Medical Center, 21 Namdong-daero 774beon-gil, Namdong-gu, Incheon 21565, Korea, (Tel) 82-32-460-8426 (Fax) 82-32-460-3668 (E-mail) dr632@gilhospital.com

Received: August 18, 2015; Revised: September 23, 2015; Accepted: September 30, 2015

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Background

Extracorporeal circulation (ECC) can induce alterations in blood viscoelasticity and cause red blood cell (RBC) aggregation. In this study, the authors evaluated the effects of pump flow pulsatility on blood viscoelasticity and RBC aggregation.

Methods

Mongrel dogs were randomly assigned to two groups: a nonpulsatile pump group (n=6) or a pulsatile pump group (n=6). After ECC was started at a pump flow rate of 80 mL/kg/min, cardiac fibrillation was induced. Blood sampling was performed before and at 1, 2, and 3 hours after ECC commencement. To eliminate bias induced by hematocrit and plasma, all blood samples were adjusted to a hematocrit of 45% using baseline plasma. Blood viscoelasticity, plasma viscosity, hematocrit, arterial blood gas analysis, central venous O2 saturation, and lactate were measured.

Results

The blood viscosity and aggregation index decreased abruptly 1 hour after ECC and then remained low during ECC in both groups, but blood elasticity did not change during ECC. Blood viscosity, blood elasticity, plasma viscosity, and the aggregation index were not significantly different in the groups at any time. Hematocrit decreased abruptly 1 hour after ECC in both groups due to dilution by the priming solution used.

Conclusion

After ECC, blood viscoelasticity and RBC aggregation were not different in the pulsatile and nonpulsatile groups in the adult dog model. Furthermore, pulsatile flow did not have a more harmful effect on blood viscoelasticity or RBC aggregation than nonpulsatile flow.

Keywords: Cardiopulmonary bypass, Hematology, Blood, Extracorporeal circulation

Extracorporeal circulation (ECC) causes red blood cells (RBC) and plasma to change in many ways [14]. These changes are largely due to the adverse effects of the heart-lung machine caused by non-physiological contact between blood and artificial surfaces [1], the effects of mechanical shear stress on blood cells [2], associated hemodilution [3], and nonpulsatile perfusion flow [4]. In particular, these effects of EEC on RBCs and plasma cause alterations of hemorheology, such as blood viscoelasticity and RBC aggregation. Blood viscoelasticity is an intrinsic property that governs flow throughout the circulatory system in response to pressure developed by the heart [5] and is affected by hematocrit (Hct), temperature, plasma viscosity, RBC deformability, and aggregation tendency [6,7]. RBC aggregation is mainly determined by plasma protein composition and the surface properties of RBCs, which change according to plasma concentrations of acute phase reactants in inflammatory disorders [8]. Furthermore, RBC aggregation is known to fall during cardiopulmonary bypass (CPB) because of hemodilution [9,10].

The comparative effects of pulsatile and nonpulsatile flow in regard to blood trauma remain debatable [11], and studies concluding that blood trauma is related to flow type have generally focused only on hemolysis. In this study, we investigated whether pulsatile perfusion has more harmful effects on blood viscoelasticity and RBC aggregation than nonpulsatile perfusion.

1) Anesthesia and surgical method

All animals were treated according to the Guide for the Care and Use of Laboratory Animals issued by the Korea University School of Medicine. Twelve mongrel dogs, weighing 27.24±5.20 kg (range, 23–32 kg), were randomly assigned to a nonpulsatile group (NP group, n=6) or a pulsatile group (P group, n=6). Animals were premedicated with intramuscular ketamine (10 mg/kg) and placed on a surgery table after weighing. An intravenous fluid route was established at the upper foreleg. After inducing general anesthesia with thiopental sodium (5–10 mg/kg) and vecuronium bromide (0.1 mg/kg), a 6–7 French endotracheal tube was inserted, and anesthesia was maintained using a N2O/O2 gas mixture (2 L/min of each). Mechanical ventilation was maintained at a tidal volume of 10–15 mL/kg and a respiratory rate of 20–25 breaths/min.

To monitor hemodynamic data and to obtain blood samples, a 20 G catheter containing a pressure transducer was inserted through the right femoral artery and a 16 G catheter was inserted through the right femoral vein for venous blood gas analysis.

Median sternotomy was performed in the supine position, heparin (3 mg/kg) was injected, the ascending aorta was cannulated (18 Fr), and the right atrium was subjected to bicaval cannulation (22 Fr). These cannula were then connected to a nonpulsatile centrifugal pump (Bio-Source TM200; Biomedicus, Minneapolis, MN, USA) or a pulsatile pump (T-PLS, Twin-Pulse Life Support, SL-1000; NewheartBio Co., Seoul, Korea). The extracorporeal circuit was primed with lactated Ringer’s solution. A membrane oxygenator (CAPIOX SX10R Oxygenator; Terumo Medical Co., Ann Arbor, MI, USA) was used in both groups. After measuring baseline hemodynamic parameters and blood sampling, ventricular fibrillation was induced with a 9 V battery. ECC was started at pump flow rate of 80 mL/kg/min. Body temperatures were maintained at 36°C. Hemodynamic parameters and blood sampling were performed using the same methods at baseline and 1, 2, and 3 hours after ECC commencement. At the end of the experiment, animals were euthanized in an anesthetized state.

2) Sample preparation for viscoelasticity and aggregation index measurements

At baseline (before ECC), 30 mL of arterial blood was collected from the right femoral artery, and after 1, 2, and 3 hours of EEC, 15 mL of arterial blood was extracted. These samples were kept in iced water before separating RBCs and plasma using a centrifugal separator at 2,500 rpm for 10 minutes. To eliminate bias caused by Hct and plasma, all blood samples were adjusted to a Hct of 45% using baseline plasma.

3) Plasma viscosity and blood viscoelasticity measurements

Plasma viscosity and blood viscoelasticities were measured using a Thermo Scientific HAAKE MARS rheometer (Thermo Fisher Scientific Inc., Waltham, MA, USA) at 36°C. The test unit waited for 1 minute before measuring viscosity and viscoelasticity values to allow blood to achieve a quiescent state. Sample plasma viscosity and blood viscoelasticity values were measured using a frequency of 1 Hz and logarithmically spaced shear strains ranging from 10 to 80 s−1 (shear rate 62.2, 75.5, 91.4, 110.8, 134.1, 162.6, 197.0, 238.6, 289.1, 350.2, 424.1, and 513.9 s−1). The viscoelastic properties of a fluid can be calculated using the equation.

μ=viscoelastic properties of a fluid=μ-iμ[ 5]μ=viscosity,μ=elasticity

4) Aggregation index

A microfluidic device was developed for measuring static aggregation. The device was composed of a NEMESYS syringe pump (Cetoni GmbH, Korbussen, Germany), a 532 nm lase pointer (LuckyDuck; Leadlight Technology Inc., Tao-Yuan, Taiwan) as a light source, a photomultiplier tube (PMT; Dongwoo Optron, Gwangju, Korea) as a detector, and a height gauge (Mitutoyo, Tokyo, Japan) to control the laser pointer. Signals were acquired using a data acquisition (DAQ) board and LabView (National Instruments Inc., Austin, TX, USA). Because flow rates were lower at the periphery of the PMT flow stream, flow in the measurement area was almost stopped for measurements. The infusion and withdrawal profile of the syringe pump was adjusted to disaggregate whole blood cells at rest and to quickly stop the flow stream in a short period of time. The zero flow condition was verified by examining flow streams under a microscope. During this stoppage, blood flow could not move into the large volume at the side, and the rest of the blood tended to move into the main channel. This reduced noise-induced problems owing to the uninterrupted flow. This setup made it possible to measure the static aggregation index (AI). The light emitted by the laser pointer was transmitted to the PMT through whole blood cells, and electrical signals produced by the PMT were transferred from the DAQ board to the LabView program. AIs during quiescent flow were calculated using data for 100 seconds based on the completed time of the withdrawal period for a syringe pump, as previously described [12].

5) Blood test

Arterial blood gas analysis, venous blood gas analysis, lactate, and Hct were measured at baseline and after 1, 2, and 3 hours of ECC.

6) Statistical analysis

The Mann-Whitney test was used to analyze differences between groups. Longitudinal comparisons within groups were performed using Kruskal-Wallis variance analysis followed by Dunn’s test. The analysis was conducted using SPSS ver. 10.0 for Windows (SPSS Inc., Chicago, IL, USA), and statistical significance was accepted for p-values <0.05. Results are expressed as means±standard deviations.

Body weights (NP, 26.0±3.1 kg; P, 25.7±2.3 kg; p=0.833) and total amounts of Ringer’s solution infused (NP, 5,433.3±1,645.2 mL; P, 6,183.3±2,139.5 mL; p=0.512) were similar in the P and NP groups.

1) Blood viscoelasticity

Blood viscoelasticity has two components: viscosity and elasticity. Blood viscosity decreased abruptly after 1 hour of ECC and then remained low. However, no significant intergroup differences were observed (Fig. 1). Blood viscosity at baseline was significantly higher than at 1 hour (at 289.1 and 513.9 s−1) in the P group, and baseline blood viscosity was significantly higher at all shear rates in the NP group (Fig. 1). Blood elasticity was constant during ECC in both groups and no significant intergroup difference was observed (Fig. 2).

2) Aggregation index

Mean AI values abruptly decreased after 1 hour of ECC in both groups, and no significantly intergroup difference was found.

3) Hematocrit, plasma viscosity, lactate, and central venous oxygen saturation

Hct and plasma viscosity decreased abruptly after 1 hour of ECC and then remained low during ECC (p<0.05). However, no significant intergroup difference was observed (Table 1). Lactate was significantly higher and ScvO2 (central venous oxygen saturation) was significantly lower at 1 hour in both groups (p<0.05), but again no significant intergroup difference was evident (Table 1).

ECC causes RBC damage, the best-known example of which is hemolysis. However, ECC also induces sub-hemolytic blood traumas, such as RBC aggregation and blood viscoelasticity changes [13]. In the present study, RBC aggregation decreased significantly during ECC, and it has been previously reported that RBC aggregation decreases after CPB because of hemodilution [9,10]. This has been shown to be primarily due to decreases in fibrinogen concentration in plasma [9,10]. Unlike previous studies, we adjusted all blood samples used for aggregation measurement to a Hct level of 45% using baseline plasma, and thus the decreased aggregation observed in the present study was not due to hemodilution only. Furthermore, there was no difference in the AI between the P and NP groups, which suggests that perfusion type has little effect on RBC aggregation.

Blood viscosity decreased during ECC regardless of perfusion type in the present study with no intergroup difference. Blood elasticity remained constant during ECC in both groups and, no elasticity difference was observed between the two groups. Undar et al. [14] reported that viscosity and elasticity changes induced by pulsatile flow during ECC were less than those induced by nonpulsatile flow during deep hypothermic circulatory arrest. Blood viscoelasticity depends on a number of factors, such as Hct, temperature, plasma viscosity, RBC deformability, aggregation tendency, and plasma composition [57]. We believe that the different results obtained by Undar et al. [14] and ourselves were caused by the use of different methods of measuring viscoelasticity and temperature during ECC. We conducted ECC at 36°C, whereas Undar et al. [14] measured viscoelasticity under hypothermic conditions. In addition, Undar et al. [14] did not adjust for Hct level or fix the plasma protein level. Furthermore, they used a neonatal piglet model, while we used an adult dog model. RBC aggregation and plasma viscosity are known to be lower in infants than in adults [15]. Despite the debate regarding the superiority of pulsatile flow with respect to organ protection during ECC in adults, general agreement has been reached that pulsatile flow is beneficial in pediatric patients [16]. Thus, it appears that the protective effect of pulsatile flow on blood cells might differ in pediatric and adult patients. Nonetheless, in the present study, we did not find any significant viscoelasticity difference between pulsatile and nonpulsatile flow during ECC in an adult dog model.

This study has some limitations that warrant consideration. First, the number of study subjects was small. Second, excessive hemodilution caused by circuit priming could have induced tissue hypoxia, generated oxygen free radicals, and thus adversely affected RBCs [1723] and masked the effects of flow type on blood viscoelasticity and RBC aggregation. Third, RBC aggregation during ECC does not precisely reflect in vivo RBC aggregation, because of the adjustment made for Hct and plasma composition. Accordingly, we suggest more studies be conducted on a larger number of animals to confirm the effect of pulsatile flow on blood viscoelasticity and RBC aggregation in adults.

In summary, we found no difference between pulsatile and nonpulsatile flow with respect to RBC aggregation or blood viscoelasticity in an adult ECC model.

This study was supported by a Grant of the Samsung Vein Clinic Network (Daejeon, Anyang, Cheongju, Cheonan; Fund No. KTCS04-046).

Go to Figures
Fig. 1.(A) Viscosity changes of pulsatile group. (B) Viscosity change of nonpulsatile group. The viscosity of the adjusted whole blood is shown in shear rates ranging from 62.2 to 513.9 s?1 in logarithmic space. There was no difference between the two groups, but the viscosity of the two groups decreased abruptly 1 hour after ECC and remained low during ECC. ECC, extracorporeal circulation; cP, centipoise. a)p<0.05 between basal and 1 hour.
Fig. 2.Elasticity. There was no difference between the two groups. cP, centipoise.

Changes in laboratory results

VariableGroupBasal1 Hour2 Hours3 Hoursp-valuea)
PO2NP143.8±70.8c)269.8±69.2d)263.2±85.2d)271.3±78.6d)0.02
P206.7±95.7226.5±61.6235.7±70.3250.2±106.90.85
p-valueb)0.240.310.940.82
Hematocrit (%)NP34.4±4.5c)19.6±1.8d)18±4.2d)16.6±4.2d)<0.001
P32.6±2.5c)16.7±3.7d)16±4.9d)13.9±4.6d)<0.001
p-valueb)0.380.130.380.42
Lactate (mmol/L)NP3.6±1.1c)9.3±0.7d)9.6±1.8d)11.4±3.2d)<0.001
P2.5±1.7c)7.8±2.9d)10.2±2.6d,e)12.3±2.8e)<0.001
p-valueb)0.230.470.930.75
Central venous oxygen saturation (%)NP51.3±17.4c)32.5±10.8d)18.7±4.3e)19.2±5.9e)<0.001
P52.5±15.4c)35.2±19.2d)22.5±11.9d)26±4d)0.01
p-valueb)1.01.00.330.08
Plasma viscosity (cP)NP1.4±0.1c)1.2±0.1d)1.1±0.1d)1.2±0.1d)<0.001
P1.5±0.31.2±0.11.3±0.21.2±0.20.08
p-valueb)0.380.340.340.42
Aggregation index (%)NP49.33±3.93c)37.83±10.98d)32.67±5.85d)29.67±6.12d)0.001
P54.0±0.97c)37.33±11.50d)33.67±12.45d)32.67±13.01d)0.02
p-valueb)0.381.00.940.75

Values are presented as mean±standard deviation.

NP, nonpulsatile group; P, pulsatile group.

a)The significances of longitudinal intragroup differences were determined using the Kruskal-Wallis test.

b)The significances of intergroup differences were determined using the Mann-Whitney test.

c,d,e)Same letters indicate non-significant differences between groups as determined using Dunn’s test.


  1. Benedetti, M, De Caterina, R, and Bionda, A (1990). Blood-artificial surface interactions during cardiopulmonary bypass: a comparative study of four oxygenators. Int J Artif Organs. 13, 488-97.
    Pubmed
  2. Gu, YJ, Boonstra, PW, Graaff, R, Rijnsburger, AA, Mungroop, H, and van Oeveren, W (2000). Pressure drop, shear stress, and activation of leukocytes during cardiopulmonary bypass: a comparison between hollow fiber and flat sheet membrane oxygenators. Artif Organs. 24, 43-8.
    Pubmed CrossRef
  3. Milam, JD, Austin, SF, Martin, RF, Keats, AS, and Cooley, DA (1981). Alteration of coagulation and selected clinical chemistry parameters in patients undergoing open heart surgery without transfusions. Am J Clin Pathol. 76, 155-62.
    Pubmed CrossRef
  4. Hickey, PR, Buckley, MJ, and Philbin, DM (1983). Pulsatile and non-pulsatile cardiopulmonary bypass: review of a counterproductive controversy. Ann Thorac Surg. 36, 720-37.
    Pubmed CrossRef
  5. Thurston, GB (1972). Viscoelasticity of human blood. Biophys J. 12, 1205-17.
    Pubmed KoreaMed CrossRef
  6. Thurston, GB (1996). Viscoelastic properties of blood and blood analogs. Advances in hemodynamics and hemorheology, How, TV, ed. New York (NY): JAI Press, pp. 1-30
    CrossRef
  7. Kasser, U, Heimburge, P, and Walitza, E (1989). Viscoelasticity of whole blood and its dependence on laboratory parameters. Clin Hemorheol Micro. 9, 307-12.
  8. Baskurt, OK, and Meiselman, HJ (2003). Blood rheology and hemodynamics. Semin Thromb Hemost. 29, 435-50.
    Pubmed CrossRef
  9. Gu, YJ, Graaff, R, and de Hoog, E (2005). Influence of hemodilution of plasma proteins on erythrocyte aggregability: an in vivo study in patients undergoing cardiopulmonary bypass. Clin Hemorheol Microcirc. 33, 95-107.
    Pubmed
  10. Morariu, AM, Gu, YJ, Huet, RC, Siemons, WA, Rakhorst, G, and Oeveren, WV (2004). Red blood cell aggregation during cardiopulmonary bypass: a pathogenic cofactor in endothelial cell activation?. Eur J Cardiothorac Surg. 26, 939-46.
    Pubmed CrossRef
  11. Qian, KX, Zeng, P, Ru, WM, Yuan, HY, Feng, ZG, and Li, I (2000). How to produce a pulsatile flow with low haemolysis?. J Med Eng Technol. 24, 227-9.
    CrossRef
  12. Hardeman, MR, Goedhart, PT, Dobbe, JG, and Lettinga, KP (1994). Laser-assisted optical rotational cell analyzer (LORCA): a new instrument for measurement of various structural hemorheological parameters. Clin Hemorheol. 14, 605-18.
  13. Kameneva, MV, Antaki, JF, and Borovetz, HS (1995). Mechanisms of red blood cell trauma in assisted circulation: rheologic similarities of red blood cell transformations due to natural aging and mechanical stress. ASAIO J. 41, M457-60.
    Pubmed CrossRef
  14. Undar, A, Henderson, N, and Thurston, GB (1999). The effects of pulsatile versus nonpulsatile perfusion on blood viscoelasticity before and after deep hypothermic circulatory arrest in a neonatal piglet model. Artif Organs. 23, 717-21.
    Pubmed CrossRef
  15. Linderkamp, O (1987). Blood rheology in the newborn infant. Baillieres Clin Haematol. 1, 801-25.
    Pubmed CrossRef
  16. Alkan, T, Akcevin, A, Undar, A, Turkoglu, H, Paker, T, and Aytac, A (2006). Effects of pulsatile and nonpulsatile perfusion on vital organ recovery in pediatric heart surgery: a pilot clinical study. ASAIO J. 52, 530-5.
    Pubmed
  17. Brecher, G, and Bessis, M (1972). Present status of spiculed red cells and their relationship to the discocyte-echinocyte transformation: a critical review. Blood. 40, 333-44.
    Pubmed
  18. Reinhart, WH, and Chien, S (1987). Echinocyte-stomatocyte transformation and shape control of human red blood cells: morphological aspects. Am J Hematol. 24, 1-14.
    Pubmed CrossRef
  19. Agroyannis, B, Dalamangas, A, and Tzanatos, H (1997). Alterations in echinocyte transformation and erythrocyte sedimentation rate during hemodialysis. Artif Organs. 21, 327-30.
    Pubmed CrossRef
  20. Saltman, P (1989). Oxidative stress: a radical view. Semin Hematol. 26, 249-56.
    Pubmed
  21. Snyder, LM, Fortier, NL, and Trainor, J (1985). Effect of hydrogen peroxide exposure on normal human erythrocyte deformability, morphology, surface characteristics, and spectrin-hemoglobin cross-linking. J Clin Invest. 76, 1971-7.
    Pubmed KoreaMed CrossRef
  22. Hashimoto, H, Mio, T, and Sumino, K (1996). Lipid abnormalities of erythrocyte membranes in hemodialysis patients with chronic renal failure. Clin Chim Acta. 252, 137-45.
    Pubmed CrossRef
  23. Luciak, M, and Trznadel, K (1991). Free oxygen species metabolism during haemodialysis with different membranes. Nephrol Dial Transplant. 6, 66-70.
    Pubmed

Article

Basic Research

Korean J Thorac Cardiovasc Surg 2016; 49(3): 145-150

Published online June 5, 2016 https://doi.org/10.5090/kjtcs.2016.49.3.145

Copyright © Journal of Chest Surgery.

The Effect of Pulsatile Versus Nonpulsatile Blood Flow on Viscoelasticity and Red Blood Cell Aggregation in Extracorporeal Circulation

Chi Bum Ahn1, Yang Jun Kang2, Myoung Gon Kim2, Sung Yang2, Choon Hak Lim3, Ho Sung Son4, Ji Sung Kim5, So Young Lee5, Kuk Hui Son5, and Kyung Sun4

1Department of Molecular Medicine, Gachon University Graduate School of Medicine, 2Department of Mechatronics, Gwangju Institute of Science and Technology, 3Department of Anesthesiology and Pain Medicine, Korea University Medical Center, 4Department of Thoracic and Cardiovascular Surgery, Korea University Medical Center, 5Department of Thoracic and Cardiovascular Surgery, Gachon University Gil Medical Center, Gachon University College of Medicine

Correspondence to:Corresponding author: Kuk Hui Son, Department of Thoracic and Cardiovascular Surgery, Gachon University Gil Medical Center, 21 Namdong-daero 774beon-gil, Namdong-gu, Incheon 21565, Korea, (Tel) 82-32-460-8426 (Fax) 82-32-460-3668 (E-mail) dr632@gilhospital.com

Received: August 18, 2015; Revised: September 23, 2015; Accepted: September 30, 2015

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Background

Extracorporeal circulation (ECC) can induce alterations in blood viscoelasticity and cause red blood cell (RBC) aggregation. In this study, the authors evaluated the effects of pump flow pulsatility on blood viscoelasticity and RBC aggregation.

Methods

Mongrel dogs were randomly assigned to two groups: a nonpulsatile pump group (n=6) or a pulsatile pump group (n=6). After ECC was started at a pump flow rate of 80 mL/kg/min, cardiac fibrillation was induced. Blood sampling was performed before and at 1, 2, and 3 hours after ECC commencement. To eliminate bias induced by hematocrit and plasma, all blood samples were adjusted to a hematocrit of 45% using baseline plasma. Blood viscoelasticity, plasma viscosity, hematocrit, arterial blood gas analysis, central venous O2 saturation, and lactate were measured.

Results

The blood viscosity and aggregation index decreased abruptly 1 hour after ECC and then remained low during ECC in both groups, but blood elasticity did not change during ECC. Blood viscosity, blood elasticity, plasma viscosity, and the aggregation index were not significantly different in the groups at any time. Hematocrit decreased abruptly 1 hour after ECC in both groups due to dilution by the priming solution used.

Conclusion

After ECC, blood viscoelasticity and RBC aggregation were not different in the pulsatile and nonpulsatile groups in the adult dog model. Furthermore, pulsatile flow did not have a more harmful effect on blood viscoelasticity or RBC aggregation than nonpulsatile flow.

Keywords: Cardiopulmonary bypass, Hematology, Blood, Extracorporeal circulation

INTRODUCTION

Extracorporeal circulation (ECC) causes red blood cells (RBC) and plasma to change in many ways [14]. These changes are largely due to the adverse effects of the heart-lung machine caused by non-physiological contact between blood and artificial surfaces [1], the effects of mechanical shear stress on blood cells [2], associated hemodilution [3], and nonpulsatile perfusion flow [4]. In particular, these effects of EEC on RBCs and plasma cause alterations of hemorheology, such as blood viscoelasticity and RBC aggregation. Blood viscoelasticity is an intrinsic property that governs flow throughout the circulatory system in response to pressure developed by the heart [5] and is affected by hematocrit (Hct), temperature, plasma viscosity, RBC deformability, and aggregation tendency [6,7]. RBC aggregation is mainly determined by plasma protein composition and the surface properties of RBCs, which change according to plasma concentrations of acute phase reactants in inflammatory disorders [8]. Furthermore, RBC aggregation is known to fall during cardiopulmonary bypass (CPB) because of hemodilution [9,10].

The comparative effects of pulsatile and nonpulsatile flow in regard to blood trauma remain debatable [11], and studies concluding that blood trauma is related to flow type have generally focused only on hemolysis. In this study, we investigated whether pulsatile perfusion has more harmful effects on blood viscoelasticity and RBC aggregation than nonpulsatile perfusion.

METHODS

1) Anesthesia and surgical method

All animals were treated according to the Guide for the Care and Use of Laboratory Animals issued by the Korea University School of Medicine. Twelve mongrel dogs, weighing 27.24±5.20 kg (range, 23–32 kg), were randomly assigned to a nonpulsatile group (NP group, n=6) or a pulsatile group (P group, n=6). Animals were premedicated with intramuscular ketamine (10 mg/kg) and placed on a surgery table after weighing. An intravenous fluid route was established at the upper foreleg. After inducing general anesthesia with thiopental sodium (5–10 mg/kg) and vecuronium bromide (0.1 mg/kg), a 6–7 French endotracheal tube was inserted, and anesthesia was maintained using a N2O/O2 gas mixture (2 L/min of each). Mechanical ventilation was maintained at a tidal volume of 10–15 mL/kg and a respiratory rate of 20–25 breaths/min.

To monitor hemodynamic data and to obtain blood samples, a 20 G catheter containing a pressure transducer was inserted through the right femoral artery and a 16 G catheter was inserted through the right femoral vein for venous blood gas analysis.

Median sternotomy was performed in the supine position, heparin (3 mg/kg) was injected, the ascending aorta was cannulated (18 Fr), and the right atrium was subjected to bicaval cannulation (22 Fr). These cannula were then connected to a nonpulsatile centrifugal pump (Bio-Source TM200; Biomedicus, Minneapolis, MN, USA) or a pulsatile pump (T-PLS, Twin-Pulse Life Support, SL-1000; NewheartBio Co., Seoul, Korea). The extracorporeal circuit was primed with lactated Ringer’s solution. A membrane oxygenator (CAPIOX SX10R Oxygenator; Terumo Medical Co., Ann Arbor, MI, USA) was used in both groups. After measuring baseline hemodynamic parameters and blood sampling, ventricular fibrillation was induced with a 9 V battery. ECC was started at pump flow rate of 80 mL/kg/min. Body temperatures were maintained at 36°C. Hemodynamic parameters and blood sampling were performed using the same methods at baseline and 1, 2, and 3 hours after ECC commencement. At the end of the experiment, animals were euthanized in an anesthetized state.

2) Sample preparation for viscoelasticity and aggregation index measurements

At baseline (before ECC), 30 mL of arterial blood was collected from the right femoral artery, and after 1, 2, and 3 hours of EEC, 15 mL of arterial blood was extracted. These samples were kept in iced water before separating RBCs and plasma using a centrifugal separator at 2,500 rpm for 10 minutes. To eliminate bias caused by Hct and plasma, all blood samples were adjusted to a Hct of 45% using baseline plasma.

3) Plasma viscosity and blood viscoelasticity measurements

Plasma viscosity and blood viscoelasticities were measured using a Thermo Scientific HAAKE MARS rheometer (Thermo Fisher Scientific Inc., Waltham, MA, USA) at 36°C. The test unit waited for 1 minute before measuring viscosity and viscoelasticity values to allow blood to achieve a quiescent state. Sample plasma viscosity and blood viscoelasticity values were measured using a frequency of 1 Hz and logarithmically spaced shear strains ranging from 10 to 80 s−1 (shear rate 62.2, 75.5, 91.4, 110.8, 134.1, 162.6, 197.0, 238.6, 289.1, 350.2, 424.1, and 513.9 s−1). The viscoelastic properties of a fluid can be calculated using the equation.

μ=viscoelastic properties of a fluid=μ-iμ[ 5]μ=viscosity,μ=elasticity

4) Aggregation index

A microfluidic device was developed for measuring static aggregation. The device was composed of a NEMESYS syringe pump (Cetoni GmbH, Korbussen, Germany), a 532 nm lase pointer (LuckyDuck; Leadlight Technology Inc., Tao-Yuan, Taiwan) as a light source, a photomultiplier tube (PMT; Dongwoo Optron, Gwangju, Korea) as a detector, and a height gauge (Mitutoyo, Tokyo, Japan) to control the laser pointer. Signals were acquired using a data acquisition (DAQ) board and LabView (National Instruments Inc., Austin, TX, USA). Because flow rates were lower at the periphery of the PMT flow stream, flow in the measurement area was almost stopped for measurements. The infusion and withdrawal profile of the syringe pump was adjusted to disaggregate whole blood cells at rest and to quickly stop the flow stream in a short period of time. The zero flow condition was verified by examining flow streams under a microscope. During this stoppage, blood flow could not move into the large volume at the side, and the rest of the blood tended to move into the main channel. This reduced noise-induced problems owing to the uninterrupted flow. This setup made it possible to measure the static aggregation index (AI). The light emitted by the laser pointer was transmitted to the PMT through whole blood cells, and electrical signals produced by the PMT were transferred from the DAQ board to the LabView program. AIs during quiescent flow were calculated using data for 100 seconds based on the completed time of the withdrawal period for a syringe pump, as previously described [12].

5) Blood test

Arterial blood gas analysis, venous blood gas analysis, lactate, and Hct were measured at baseline and after 1, 2, and 3 hours of ECC.

6) Statistical analysis

The Mann-Whitney test was used to analyze differences between groups. Longitudinal comparisons within groups were performed using Kruskal-Wallis variance analysis followed by Dunn’s test. The analysis was conducted using SPSS ver. 10.0 for Windows (SPSS Inc., Chicago, IL, USA), and statistical significance was accepted for p-values <0.05. Results are expressed as means±standard deviations.

RESULTS

Body weights (NP, 26.0±3.1 kg; P, 25.7±2.3 kg; p=0.833) and total amounts of Ringer’s solution infused (NP, 5,433.3±1,645.2 mL; P, 6,183.3±2,139.5 mL; p=0.512) were similar in the P and NP groups.

1) Blood viscoelasticity

Blood viscoelasticity has two components: viscosity and elasticity. Blood viscosity decreased abruptly after 1 hour of ECC and then remained low. However, no significant intergroup differences were observed (Fig. 1). Blood viscosity at baseline was significantly higher than at 1 hour (at 289.1 and 513.9 s−1) in the P group, and baseline blood viscosity was significantly higher at all shear rates in the NP group (Fig. 1). Blood elasticity was constant during ECC in both groups and no significant intergroup difference was observed (Fig. 2).

2) Aggregation index

Mean AI values abruptly decreased after 1 hour of ECC in both groups, and no significantly intergroup difference was found.

3) Hematocrit, plasma viscosity, lactate, and central venous oxygen saturation

Hct and plasma viscosity decreased abruptly after 1 hour of ECC and then remained low during ECC (p<0.05). However, no significant intergroup difference was observed (Table 1). Lactate was significantly higher and ScvO2 (central venous oxygen saturation) was significantly lower at 1 hour in both groups (p<0.05), but again no significant intergroup difference was evident (Table 1).

DISCUSSION

ECC causes RBC damage, the best-known example of which is hemolysis. However, ECC also induces sub-hemolytic blood traumas, such as RBC aggregation and blood viscoelasticity changes [13]. In the present study, RBC aggregation decreased significantly during ECC, and it has been previously reported that RBC aggregation decreases after CPB because of hemodilution [9,10]. This has been shown to be primarily due to decreases in fibrinogen concentration in plasma [9,10]. Unlike previous studies, we adjusted all blood samples used for aggregation measurement to a Hct level of 45% using baseline plasma, and thus the decreased aggregation observed in the present study was not due to hemodilution only. Furthermore, there was no difference in the AI between the P and NP groups, which suggests that perfusion type has little effect on RBC aggregation.

Blood viscosity decreased during ECC regardless of perfusion type in the present study with no intergroup difference. Blood elasticity remained constant during ECC in both groups and, no elasticity difference was observed between the two groups. Undar et al. [14] reported that viscosity and elasticity changes induced by pulsatile flow during ECC were less than those induced by nonpulsatile flow during deep hypothermic circulatory arrest. Blood viscoelasticity depends on a number of factors, such as Hct, temperature, plasma viscosity, RBC deformability, aggregation tendency, and plasma composition [57]. We believe that the different results obtained by Undar et al. [14] and ourselves were caused by the use of different methods of measuring viscoelasticity and temperature during ECC. We conducted ECC at 36°C, whereas Undar et al. [14] measured viscoelasticity under hypothermic conditions. In addition, Undar et al. [14] did not adjust for Hct level or fix the plasma protein level. Furthermore, they used a neonatal piglet model, while we used an adult dog model. RBC aggregation and plasma viscosity are known to be lower in infants than in adults [15]. Despite the debate regarding the superiority of pulsatile flow with respect to organ protection during ECC in adults, general agreement has been reached that pulsatile flow is beneficial in pediatric patients [16]. Thus, it appears that the protective effect of pulsatile flow on blood cells might differ in pediatric and adult patients. Nonetheless, in the present study, we did not find any significant viscoelasticity difference between pulsatile and nonpulsatile flow during ECC in an adult dog model.

This study has some limitations that warrant consideration. First, the number of study subjects was small. Second, excessive hemodilution caused by circuit priming could have induced tissue hypoxia, generated oxygen free radicals, and thus adversely affected RBCs [1723] and masked the effects of flow type on blood viscoelasticity and RBC aggregation. Third, RBC aggregation during ECC does not precisely reflect in vivo RBC aggregation, because of the adjustment made for Hct and plasma composition. Accordingly, we suggest more studies be conducted on a larger number of animals to confirm the effect of pulsatile flow on blood viscoelasticity and RBC aggregation in adults.

In summary, we found no difference between pulsatile and nonpulsatile flow with respect to RBC aggregation or blood viscoelasticity in an adult ECC model.

ACKNOWLEDGMENTS

This study was supported by a Grant of the Samsung Vein Clinic Network (Daejeon, Anyang, Cheongju, Cheonan; Fund No. KTCS04-046).

Fig 1.

Figure 1.(A) Viscosity changes of pulsatile group. (B) Viscosity change of nonpulsatile group. The viscosity of the adjusted whole blood is shown in shear rates ranging from 62.2 to 513.9 s?1 in logarithmic space. There was no difference between the two groups, but the viscosity of the two groups decreased abruptly 1 hour after ECC and remained low during ECC. ECC, extracorporeal circulation; cP, centipoise. a)p<0.05 between basal and 1 hour.
Journal of Chest Surgery 2016; 49: 145-150https://doi.org/10.5090/kjtcs.2016.49.3.145

Fig 2.

Figure 2.Elasticity. There was no difference between the two groups. cP, centipoise.
Journal of Chest Surgery 2016; 49: 145-150https://doi.org/10.5090/kjtcs.2016.49.3.145

Table 1 . Changes in laboratory results.

VariableGroupBasal1 Hour2 Hours3 Hoursp-valuea)
PO2NP143.8±70.8c)269.8±69.2d)263.2±85.2d)271.3±78.6d)0.02
P206.7±95.7226.5±61.6235.7±70.3250.2±106.90.85
p-valueb)0.240.310.940.82
Hematocrit (%)NP34.4±4.5c)19.6±1.8d)18±4.2d)16.6±4.2d)<0.001
P32.6±2.5c)16.7±3.7d)16±4.9d)13.9±4.6d)<0.001
p-valueb)0.380.130.380.42
Lactate (mmol/L)NP3.6±1.1c)9.3±0.7d)9.6±1.8d)11.4±3.2d)<0.001
P2.5±1.7c)7.8±2.9d)10.2±2.6d,e)12.3±2.8e)<0.001
p-valueb)0.230.470.930.75
Central venous oxygen saturation (%)NP51.3±17.4c)32.5±10.8d)18.7±4.3e)19.2±5.9e)<0.001
P52.5±15.4c)35.2±19.2d)22.5±11.9d)26±4d)0.01
p-valueb)1.01.00.330.08
Plasma viscosity (cP)NP1.4±0.1c)1.2±0.1d)1.1±0.1d)1.2±0.1d)<0.001
P1.5±0.31.2±0.11.3±0.21.2±0.20.08
p-valueb)0.380.340.340.42
Aggregation index (%)NP49.33±3.93c)37.83±10.98d)32.67±5.85d)29.67±6.12d)0.001
P54.0±0.97c)37.33±11.50d)33.67±12.45d)32.67±13.01d)0.02
p-valueb)0.381.00.940.75

Values are presented as mean±standard deviation..

NP, nonpulsatile group; P, pulsatile group..

a)The significances of longitudinal intragroup differences were determined using the Kruskal-Wallis test.

b)The significances of intergroup differences were determined using the Mann-Whitney test.

c,d,e)Same letters indicate non-significant differences between groups as determined using Dunn’s test.


References

  1. Benedetti, M, De Caterina, R, and Bionda, A (1990). Blood-artificial surface interactions during cardiopulmonary bypass: a comparative study of four oxygenators. Int J Artif Organs. 13, 488-97.
    Pubmed
  2. Gu, YJ, Boonstra, PW, Graaff, R, Rijnsburger, AA, Mungroop, H, and van Oeveren, W (2000). Pressure drop, shear stress, and activation of leukocytes during cardiopulmonary bypass: a comparison between hollow fiber and flat sheet membrane oxygenators. Artif Organs. 24, 43-8.
    Pubmed CrossRef
  3. Milam, JD, Austin, SF, Martin, RF, Keats, AS, and Cooley, DA (1981). Alteration of coagulation and selected clinical chemistry parameters in patients undergoing open heart surgery without transfusions. Am J Clin Pathol. 76, 155-62.
    Pubmed CrossRef
  4. Hickey, PR, Buckley, MJ, and Philbin, DM (1983). Pulsatile and non-pulsatile cardiopulmonary bypass: review of a counterproductive controversy. Ann Thorac Surg. 36, 720-37.
    Pubmed CrossRef
  5. Thurston, GB (1972). Viscoelasticity of human blood. Biophys J. 12, 1205-17.
    Pubmed KoreaMed CrossRef
  6. Thurston, GB (1996). Viscoelastic properties of blood and blood analogs. Advances in hemodynamics and hemorheology, How, TV, ed. New York (NY): JAI Press, pp. 1-30
    CrossRef
  7. Kasser, U, Heimburge, P, and Walitza, E (1989). Viscoelasticity of whole blood and its dependence on laboratory parameters. Clin Hemorheol Micro. 9, 307-12.
  8. Baskurt, OK, and Meiselman, HJ (2003). Blood rheology and hemodynamics. Semin Thromb Hemost. 29, 435-50.
    Pubmed CrossRef
  9. Gu, YJ, Graaff, R, and de Hoog, E (2005). Influence of hemodilution of plasma proteins on erythrocyte aggregability: an in vivo study in patients undergoing cardiopulmonary bypass. Clin Hemorheol Microcirc. 33, 95-107.
    Pubmed
  10. Morariu, AM, Gu, YJ, Huet, RC, Siemons, WA, Rakhorst, G, and Oeveren, WV (2004). Red blood cell aggregation during cardiopulmonary bypass: a pathogenic cofactor in endothelial cell activation?. Eur J Cardiothorac Surg. 26, 939-46.
    Pubmed CrossRef
  11. Qian, KX, Zeng, P, Ru, WM, Yuan, HY, Feng, ZG, and Li, I (2000). How to produce a pulsatile flow with low haemolysis?. J Med Eng Technol. 24, 227-9.
    CrossRef
  12. Hardeman, MR, Goedhart, PT, Dobbe, JG, and Lettinga, KP (1994). Laser-assisted optical rotational cell analyzer (LORCA): a new instrument for measurement of various structural hemorheological parameters. Clin Hemorheol. 14, 605-18.
  13. Kameneva, MV, Antaki, JF, and Borovetz, HS (1995). Mechanisms of red blood cell trauma in assisted circulation: rheologic similarities of red blood cell transformations due to natural aging and mechanical stress. ASAIO J. 41, M457-60.
    Pubmed CrossRef
  14. Undar, A, Henderson, N, and Thurston, GB (1999). The effects of pulsatile versus nonpulsatile perfusion on blood viscoelasticity before and after deep hypothermic circulatory arrest in a neonatal piglet model. Artif Organs. 23, 717-21.
    Pubmed CrossRef
  15. Linderkamp, O (1987). Blood rheology in the newborn infant. Baillieres Clin Haematol. 1, 801-25.
    Pubmed CrossRef
  16. Alkan, T, Akcevin, A, Undar, A, Turkoglu, H, Paker, T, and Aytac, A (2006). Effects of pulsatile and nonpulsatile perfusion on vital organ recovery in pediatric heart surgery: a pilot clinical study. ASAIO J. 52, 530-5.
    Pubmed
  17. Brecher, G, and Bessis, M (1972). Present status of spiculed red cells and their relationship to the discocyte-echinocyte transformation: a critical review. Blood. 40, 333-44.
    Pubmed
  18. Reinhart, WH, and Chien, S (1987). Echinocyte-stomatocyte transformation and shape control of human red blood cells: morphological aspects. Am J Hematol. 24, 1-14.
    Pubmed CrossRef
  19. Agroyannis, B, Dalamangas, A, and Tzanatos, H (1997). Alterations in echinocyte transformation and erythrocyte sedimentation rate during hemodialysis. Artif Organs. 21, 327-30.
    Pubmed CrossRef
  20. Saltman, P (1989). Oxidative stress: a radical view. Semin Hematol. 26, 249-56.
    Pubmed
  21. Snyder, LM, Fortier, NL, and Trainor, J (1985). Effect of hydrogen peroxide exposure on normal human erythrocyte deformability, morphology, surface characteristics, and spectrin-hemoglobin cross-linking. J Clin Invest. 76, 1971-7.
    Pubmed KoreaMed CrossRef
  22. Hashimoto, H, Mio, T, and Sumino, K (1996). Lipid abnormalities of erythrocyte membranes in hemodialysis patients with chronic renal failure. Clin Chim Acta. 252, 137-45.
    Pubmed CrossRef
  23. Luciak, M, and Trznadel, K (1991). Free oxygen species metabolism during haemodialysis with different membranes. Nephrol Dial Transplant. 6, 66-70.
    Pubmed